Product Specs
Generator Set Specifications
- Maximum Rating
- 50.0 kVA
- Minimum Rating
- 50.0 kVA
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- Cat® C3.3, In-line 3, 4-cycle diesel
- Bore
- 4.1 in
- Stroke
- 5 in
- Displacement
- 201.4 in³
- Compression Ratio
- 17.25:1
- Aspiration
- Turbocharged
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length - Maximum
- 89.7 in
- Width - Maximum
- 35.4 in
- Height - Maximum
- 52 in
- Dry Weight - Genset (maximum)
- 2273 lb
Standard Equipment
- 
            
            - Engine
- 
                        - C3.3, Inline 3 cylinder, 4 stroke diesel
 
 
- 
            
            - Genset Control
- 
                        - GCCP 1.1
 
 
- 
            
            - Governor
- 
                        - Mechanical governor
 
 
- 
            
            - Alternator
- 
                        - A Frame standard alternator
 
 
- 
            
            - Fuel Storage
- 
                        - Single wall 8 hour fuel tank
 
 
- 
            
            - Enclosure
- 
                        - Cat GC enclosure
 
 
- 
            
            - Air, Cooling & Exhaust
- 
                        - Enclosure silencer
 
 
- 
            
            - General
- 
                        - Engine and alternator pre-paint, Caterpillar yellow
 
 
Attachments
- 
            
            - Certification
- 
                        - Certificate of Conformance
- Australia, CIS, Gulf Certification
 
 
- 
            
            - Alternator Requirements
- 
                        - Space heater
 
 
- 
            
            - Auxiliary Supply Voltage
- 
                        - 120V
 
 
- 
            
            - Fuel Storage
- 
                        - Dual wall 8 hour fuel tank
- Single wall tank with containment
- Low fuel level alarm
- Low fuel level shutdown
- High fuel level alarm
 
 
- 
            
            - Genset Control
- 
                        - Battery charger
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Earth leakage
- Earth fault
- Emergency stop with key
- USB to RS485 Communications device
- Panel mounted audible alarm
- Battery
- Low coolant level shutdown
- Standby Pack (Smart Jacket water heater, Battery charger)
- Coolant heater
 
 
- 
            
            - Circuit Breaker
- 
                        - 3 Pole Circuit breaker 80A
- 3 Pole Circuit breaker 63A
- 3 Pole Circuit breaker 100A
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 80A
- 4 Pole Circuit breaker 63A
- 4 Pole Circuit breaker 100A
- 4 Pole Circuit breaker 125A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 200A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
 
 
- 
            
            - Testing & Packaging
- 
                        - PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF
 
 


 Exterior View
 